0%

AVIONICS BAY SMOKE DETECTION - The SMOKE L(R) AVNCS SMOKE alert is triggered if, in the left(right) avionics ventilation circuit:

Correct! Wrong!

MAIN LANDING GEAR FIRE PROTECTION - The Fire Protection System (FPS) detects overheat in the MLG bay.

Correct! Wrong!

The FPS uses two identical loops (A and B) for each sensitive zone. The FPF receives information from the two loops. The FPF provides information to the ECAM to generate applicable fire warnings or loop cautions.

ENGINE FIRE DETECTION - The Fire Protection System (FPS) uses two identical loops (A and B) to monitor the sensitive zones. What are they?

Correct! Wrong!

These zones are protected, because they are heat sensitive zones in which a fire could potentially start.

Can the flight crew press the ENGINE FIRE p/b in the case of an engine tailpipe fire?

Correct! Wrong!

CARGO COMPARTMENT PROTECTION - The Smoke Detection System (SDS) has smoke detectors in the forward and aft/bulk cargo compartments. These detectors are in cavities within the ceiling panels. Each cargo compartment cavity has _____ detectors.

Correct! Wrong!

CARGO COMPARTMENT PROTECTION - When the flight crew presses the assigned push-button, the extinguisher agent is released into the affected cargo compartment. A diverter valve directs extinguisher agent to either the forward or aft/bulk cargo compartment.

Correct! Wrong!

APU FIRE - On ground, if a fire is detected, the Fire Protection System (FPS) automatically activates the extinguishing system.

Correct! Wrong!

APU FIRE - The Fire Protection System (FPS) uses:

Correct! Wrong!

The Fire Protection Function (FPF) receives information from the two loops. The FPF provides information to the ECAM to generate applicable fire warnings or loop cautions.

WASTEBIN FIRE EXTINGUISHING - The wastebin in each lavatory has a built-in, automatic, fire extinguishing system.

Correct! Wrong!

AVIONICS BAY SMOKE DETECTION - The "SMOKE L(R) AVNCS DET FAULT" alert is triggered if one or both detectors fail in the left(right) avionics ventilation circuit.

Correct! Wrong!

Advertisement

WASTEBIN FIRE EXTINGUISHING - The wastebin in each lavatory has:

Correct! Wrong!

The avionics bay has a Smoke Detection System (SDS) and a Fire Detection System (FDS).

Correct! Wrong!

Each avionics ventilation circuit has two smoke detectors. They are in the air extraction ducts.

APU FIRE - On ground, if the FPF detects a fire:

Correct! Wrong!

LAVATORY SMOKE DETECTION - If the SDF detects smoke in any lavatory:

Correct! Wrong!

CARGO COMPARTMENT PROTECTION - If smoke is detected in a cargo compartment, the ventilation:

Correct! Wrong!

CARGO COMPARTMENT PROTECTION - The Smoke Detection System (SDS) uses detectors that are in cavities within the ceiling panels. There are:

Correct! Wrong!

Airbus A350 – Fire Protection