The hydraulic system monitoring unit (HSMU) processes:
Correct!
Wrong!
With a single hydraulic system failure the flight control law is:
Correct!
Wrong!
The Airbus A330 hydraulic system has:
Correct!
Wrong!
A pump, driven by Engine 2 pressurizes the yellow system. Flight crew can also use a hand pump to pressurize the yellow system, in order to operate the cargo doors when no electrical power is available.
Correct!
Wrong!
The BLUE hydraulic system includes operation of:
Correct!
Wrong!
In flight and during approach the FLAP handle is at 2. If an engine 2 failure occurs:
Correct!
Wrong!
There is a BLUE LO AIR PRESS alarm and there is a 'FAULT' indication on BLUE ENG 1 pump pb. Which one of the following statements is true?
Correct!
Wrong!
After Takeoff, one engine fails prior to the Landing Gear retraction. When the Gear handle is selected 'UP':
Correct!
Wrong!
The GREEN ELEC pump starts automatically:
Correct!
Wrong!
With the GREEN hydraulic system lost, the antiskid system is:
Correct!
Wrong!
Advertisement
The Ram Air Turbine (RAT) deployment is automatically controlled by the HSMU (Hydraulic System Monitoring Unit) when:
Correct!
Wrong!
In case of GREEN reservoir LO LEVEL the HSMU (Hydraulic System Monitoring Unit) will:
Correct!
Wrong!
During landing gear retraction, the engine 1 fails and the GREEN ELEC pump is automatically activated. How will it stop?
Correct!
Wrong!
What indicates the amber zone on the HYD page?

Correct!
Wrong!
If the GREEN hydraulic system is lost:
Correct!
Wrong!
What is the difference between the BLUE ELEC pump and the GREEN or YELLOW ELEC pump?
Correct!
Wrong!
In the event of hydraulic green low pressure, heavy load users are isolated to give priority to:
Correct!
Wrong!
In the event of low hydraulic pressure, a priority valve cuts off hydraulic power to heavy load users (emergency generator, nosewheel steering, landing gear) in order to keep the pressure for normal braking and flight controls.
The corresponding hydraulic systems can be pressurized by:
Correct!
Wrong!
Leak measurement valves pb on the Maintenance panel:
Correct!
Wrong!
Leak measurement valves are positioned upstream of the primary flight controls. They are used for the leak measurement of each system and may only be closed on ground, by using the LEAK MEASUREMENT VALVES pb on the maintenance panel.
The hydraulic reservoirs are pressurized:
Correct!
Wrong!
Advertisement
The RAT deploys automatically in the event of an engine failure or a low level in the green and yellow or green and blue reservoirs.
Correct!
Wrong!
The RAT deploys automatically in the event of both engine failure or a low level in the green and yellow or green and blue reservoirs.
An accumulator in each system helps maintain constant pressure by covering transient demands during:
Correct!
Wrong!
What is the correct statement about the RAT?
Correct!
Wrong!
There is no possibility to transfer hydraulic fluid from one system to another.
Correct!
Wrong!
When the RAT pressurizes the green system, the aileron, elevator, and spoiler servo control operating speeds are reduced.
Correct!
Wrong!
Airbus A330 – Hydraulics