In case of trim air system fault (zone controller primary channel failure), the secondary channel of the zone controller regulated the zone temperature at:
What limitation is associated with the ram air valve?
Only open if differential pressure is lower than 1 psi.
The Ram Air valve:
Aft cargo ventilation is controlled by: The zone controller and the SDCU.
Avionics ventilation system indications may be found on which ECAM page(s)?
When the pack flow control knob is positioned to HI, air flow is:
The RAM AIR switch should be used:
In normal flight in closed circuit configuration, the avionics ventilation system controls the temperature of the cooling air by:
In the CABIN PRESSURIZATION system, the function of the safety valves is to:
Does the trim air provide the warm air or the cold air to the air conditioning system?
Advertisement
The HOT AIR valve push button controls:
What is the normal maximum cabin altitude?
An extraction fan draws ambient cabin air through the lavatories and galleys and exhausts it near the forward doors. The extraction fan runs continually when electric power is available.
An extraction fan draws ambient cabin air through the lavatories and galleys and exhausts it near the outflow valve. The extraction fan runs continually when electric power is available.
The cabin pressurization system has ____ general functions:
Ground function (fully opens the outflow valve on ground). Pre-pressurization (during takeoff, increases cabin pressure to avoid a surge in cabin pressure during rotation). Pressurization in flight (adjusts cabin altitude, and rate of change to provide passengers with a comfortable flight). Depressurization (after touchdown, gradually releases residual cabin overpressure before the ground function fully opens the outflow valve).
The pressure safety valve automatically opens at:
Low-pressure air is supplied to the mixing unit by a ground connection.
Trim air valves are controlled by:
If a pack controller fails (primary and secondary channel failure), the pack outlet air temperature is controlled by:
The purpose of the safety valve is to avoid:
Two independent pneumatic safety valves prevent cabin pressure from going too high (8.6 PSI above ambient) or too low (1 PSI below ambient). They are located on the rear pressure bulkhead, above the flotation line.
Two electric fans continuously circulate air around the avionics equipment, when the aircraft is electrically supplied.
Advertisement
Engine flow demand - When the heating or cooling demand in one zone cannot be satisfied:
When does normal depressurization occur?
When would you select PACK FLOW to HI?
ENGINE PRESSURE DEMAND - When the cooling demand in one zone cannot be satisfied, if the bleed pressure is too low, the air conditioning system controller sends a pressure demand signal to both Engine Interface Units (EIU) to increase the minimum idle and to raise the bleed pressure.
Which statement is correct regarding the illumination of the amber AFT ISOL VALVE fault light?
The HOT AIR fault light illuminates on the air conditioning panel.
A venturi in the skin of the aircraft draws air from the space around the batteries and vents it overboard. The resulting airflow ventilates the batteries.
In case of zone controller primary and secondary channel failure, what temperatures are maintained by pack one and pack two?
On the ECAM Cabin Pressure page, the outflow valve indicator changes to amber if:
Bleed air supplied from the APU (APU bleed valve open), the pack flow is automatically selected:
Advertisement
When would you select RAM AIR ON?
An emergency ram air inlet ventilates the cockpit and cabin to remove smoke, or if both packs fail. The emergency ram air inlet valve is controlled by the RAM AIR pushbutton on the AIR COND panel. This pushbutton opens the ram air valve, provided that ditching is not selected.
With APU BLEED ON and engine BLEED switches ON with engines running, what is the position of the engine bleed valves?
The avionics ventilation system is fully automatic. It cools the electrical and electronic components in the avionics compartment and on the flight deck, including the instrument and circuit breaker panels. It uses two electric fans to force the circulation of cooling air.
On the CABIN PRESS panel, with the MAN V/S CTL held in the DN position, the outflow valve will:
MANUAL PRESSURE CONTROL MODE - Due to the slow operation of the outflow valves in manual mode, and the limited resolution of the outflow valves' position on the ECAM, the visual ECAM indication of a change in the outflow valves' position can take up to _____
As the pressurization system is manually-controlled, the outflow valve does not open automatically at touchdown.
Air from the cabin goes via the inlet isolation valve to the forward cargo compartment, driven either by an extraction fan or by differential pressure in flight. A skin-mounted venturi discharges the air overboard via the outlet isolation valve.
The cargo ventilation controller controls the operation of the inlet and outlet isolation valves and the extraction fan.
In case of trim air failure, optimized temperature regulation of the corresponding zone is degraded but still available.
Optimized temperature regulation of the corresponding zone is lost.
The safety valves are _____ operated.
The mixing unit is connected to:
With the pressurization system in the automatic mode, which valves are closed when the ditching push button is selected on?
Advertisement
Pack controller, primary and secondary channel failure.
Two identical, independent, automatic digital pressurization controllers are used for system control:
Two identical, independent, digital controllers automatically control the system, by maintaining the proper cabin pressure. They receive signals from the Air Data Inertial Reference System (ADIRS), the Flight Management and Guidance Computer (FMGC), the Engine Interface Unit (EIU), and the Landing Gear Control Interface Unit (LGCIU).
When does normal pressurization occur?
Both engines are running and the APU bleed has been switched OFF. Which statement is correct?
What will cause the ENG BLEED fault light to come on?
When landing elevation is set to AUTO, the landing elevation is sent to the controller from:
Each Trim air valve optimizes the temperature by:
Which configuration is the avionics ventilation system in while airborne with no abnormals present?
Temperature control is automatic and is regulated by:
Which of the following statements is correct?
Advertisement
What ventilation configuration is displayed on the CAB PRESS page?
In case of zone controller primary and secondary channel failure, what temperatures are maintained by Packs 1 and 2
Pack controller, primary channel failure. What is the true statement?
The temperature of each aircraft zone is optimized by means of:
How many outflow valves are there?
On the CABIN PRESS panel, pushing on the MODE SEL pb gives control over:
In case of total zone controller failure:
Emergency ram air inlet - When set to "ON" the ram air valve will open and supply airflow:
When the RAM AIR pushbutton is ON, and differential pressure is below 1 PSI, the system drives the outflow valve about _____ if it is under automatic control.
What is the maximum negative differential pressure for the cabin?
Advertisement
Pressurization is normally automatic. Can you interfere with it?
Conditioning Zone regulator fault (primary channel failed):
How can you change controllers during flight?
For operation in manual mode, each cabin pressure controller has a backup section, which is powered by an independent power supply in the controller No.1 position.
On the ECAM Cabin Pressure page, the safety valve indication changes to amber if:
During Ground function operation, the outflow valve is: Fully closed.
Conditioned air is distributed to:
The air conditioning system is fully automatic. It provides continuous air renewal and maintains a constant, selected temperature in the following 3 zones : COCKPIT, FWD CABIN, AFT CABIN. These three zones are independently controlled.
How many temperature selectors are there on the A320? How many temperature zones are there?
'PACK REG' is displayed on the ECAM 'COND' page. What does it mean?
To enable Ram air to the mixture unit, The Ram air switch should be used:
Advertisement
Aft cargo indications may be found on which ECAM page(s)?
What computers control the cabin and cockpit conditioned air?
PACK FLOW CONTROL - The flight crew can use the PACK FLOW selector (or ECON FLOW pb for A321 aircraft) to adjust the pack flow for the number of passengers and for external conditions.
In flight with pressure controller 1 in use, if it fails:
What is the maximum altitude associated with the pressurization system?
Under what conditions should the pack flow controller be set to HI?
During the exterior preflight on a warm day, in what position would you expect to find the avionics ventilation system INLET and EXTRACT valves to be in?
The outflow valve is powered by:
The outflow valve assembly consists of a flush, skin-mounted, rectangular frame, carrying inward and outward opening flaps linked to the actuator. The actuator contains the drives of the two automatic motors and the manual motor. Either of two automatic motors operates the valve in automatic mode, and the manual motor operates it in manual mode.
The ventilation system for the aft cargo compartment uses hot engine bleed air (upstream of the packs), mixing it with the ambient cabin air that flows through the cargo compartment. The cargo regulating valve regulates the pressure of this hot air supply, and the trim air valve, which is modulated electrically by the controller, controls the flow.
The cargo pressure regulating valve is pneumatically operated and electrically controlled from the HOT AIR pb on the CARGO HEAT panel.
What are the different sources of air for air conditioning and pressurization?
Advertisement
The outflow valve is on the right-hand side of fuselage, behind the aft cargo compartment and above the flotation line.
The outflow valve is on the right-hand side of fuselage, behind the aft cargo compartment and below the flotation line.
Which of the following statements is correct concerning conditioned air?
What happens to the pack flow control valves during engine start?
Placing the avionics ventilation system in the smoke configuration:
When a LDG ELEV is set manually on the CABIN PRESS panel, is there still an automatic control of the cabin altitude?
Which cabin pressure controller generates excess cabin altitude and pressure signals for ECAM indication in manual mode?
The Ram Air Inlet Flaps remain open during takeoff and landing to allow extra airflow during high power situations.
During takeoff, the ram air inlet flap closes when takeoff power is set, and the main landing gear struts are compressed. During landing, it closes as soon as the main landing gear struts are compressed, as long as speed is at or above 70 kt. It opens 20 s after the speed drops below 70 kt.
With reference to the AIR COND panel, which statement is correct?
Which statement is TRUE concerning the cargo compartment ventilation?
Both pressurization auto controllers are set by the active flight plan loaded in the MCDU. The QNH entry on the MCDU Approach Performance page refines the depressurization schedule for the landing.
Advertisement
Once set to "ON" the air conditioning packs operate:
It is allowed to use simultaneously packs and LP ground unit during long stops in a hot environment.
Do not use conditioned air simultaneously from packs and LP ground unit (to avoid chattering of the non return valves).
When APU is supplying the packs, the pack controller sends a demand signal to increase airflow when a zone temperature cannot be satisfied. This signal is sent to the:
The ECB is responsible for regulating and monitoring the APU’s electrical, pneumatic, and fuel systems. It receives commands from the flight crew through switches and control panels in the cockpit, and it relays these commands to the APU. The ECB also receives feedback from various sensors and systems to ensure that the APU is operating within safe parameters.
Pressurization indications are found on which ECAM page(s)?
At what cabin altitude do you get an ECAM warning?
Pressurization controllers receive inputs from:
The zone controller optimizes temperature by action on the:
What is the function of the ram air valve?
To prepare for ditching, the flight crew must press the DITCHING pb on the CABIN PRESS control panel to close:
The cabin zone temperature sensors are ventilated by the air extracted by the lavatory and galley fans.
Advertisement
Regarding the CABIN PRESSURIZATION system, what should the differential pressure be on the ground?
What is the maximum negative differential pressure for the cabin?
Please select 2 correct answers
The ditching switch when selected sends a closure signal to the:
Hot air fault light illuminates on the air conditioning panel.
The hot air pressure regulating valve:
The PACK FLOW controller is set to NORM and yet the ECAM display shows PACK FLOW to be high. How is this possible?
What does the CARGO HEAT HOT AIR FAULT light indicate?
How many trim air valves are there?
ECAM DOOR - OXY PAGE – The cabin vertical speed (VS) is normally green. It pulses, when the VS is greater than 1 750 fpm and stops pulsing, when less than 1 650 fpm. It becomes amber, when the VS is greater than _____
If the Air Cycle Machine (ACM) fails (compressor/turbine seizure), the affected pack may be operated in heat exchanger cooling mode. Warm pre-conditioned bleed air enters the cooling path via the pack valve and goes to the primary heat exchanger. Then, the main part of the cooled air goes directly downstream of ACM turbine through the bypass valve, and the rest goes through the failed ACM.
The ACM seizure reduces the pack flow.
Advertisement
Under what conditions should the pack flow controller be set to LO?
For the Normal Operation of the CARGO COND SYSTEM:
During takeoff, the ram air inlet flap closes when takeoff power is set, and both the main landing gear and nose landing gear struts are compressed.
During takeoff, the ram air inlet flap closes when takeoff power is set, and the main landing gear struts are compressed.
Hot air pressure regulating valve failed open:
What happens when a temperature selector rotary knob is adjusted?
During normal flight, the avionics ventilation system controls the temperature of the cooling air by:
The cabin pressurization uses one outflow valve with an actuator that incorporates:
Any one of the three independent electric motors may power the outflow valve.
What position do the pack valves go to in the event of a loss of the bleed system pressure?
During the landing roll, the Ram Air Inlet flaps open when speed is less than:
What is the function of the Pack Flow selector?
Advertisement